The cooling tower is an equipment designed with a focus on the transfer of residual heat from a certain industrial process to the atmosphere, through evaporative thermal dissipation, lowering the temperature of the circulating water. The EMP (PULTRUDED MIXED STRUCTURE) 38, 45, 55, 68, 76, 86, 100 and 121 models, with air draft drawn in countercurrent to water, have induced ventilation, that is, from the inside out, with air intake horizontally and discharge of air vertically in an ascending movement, with PRFV (Fiberglass reinforced polyester) closure, and cooled water basin in concrete, with pillars and beams up to the height of the diffuser in Pultruded PRFV. Contact ALFATERM's experienced technical team and schedule a visit with one of our engineers!
Model | EMP 38 | ||
---|---|---|---|
A | 3560 | ||
B | 5600 | ||
C | 6760 | ||
D | 6550 | ||
E | 6550 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2390 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 4680 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 6000 | |
Oper. | 9120 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMP 45 | ||
---|---|---|---|
A | 3900 | ||
B | 6600 | ||
C | 6600 | ||
D | 6745 | ||
E | 6745 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2390 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 4745 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 6800 | |
Oper. | 10350 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | |||||||||||||||
09. | |||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMP 55 | ||
---|---|---|---|
A | 4400 | ||
B | 7500 | ||
C | 7500 | ||
D | 7680 | ||
E | 7680 | ||
F | N | ||
G | |||
number of filling layers | |||
2 | 2390 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5290 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 8200 | |
Oper. | 12500 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMP 68 | ||
---|---|---|---|
A | 4900 | ||
B | 8350 | ||
C | 8350 | ||
D | 8660 | ||
E | 8660 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2390 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5225 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 9800 | |
Oper. | 14900 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMP 76 | ||
---|---|---|---|
A | 5700 | ||
B | 8640 | ||
C | 8640 | ||
D | 8960 | ||
E | 8960 | ||
F | N | ||
G | |||
number of filling layers | |||
2 | 2570 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5225 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 11500 | |
Oper. | 16600 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMP 86 | ||
---|---|---|---|
A | 6100 | ||
B | 9300 | ||
C | 9300 | ||
D | 9610 | ||
E | 9610 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2570 | ||
3 | |||
4 | 2670 | ||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5225 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 12100 | |
Oper. | 18400 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMP 100 | ||
---|---|---|---|
A | 6100 | ||
B | 10080 | ||
C | 10080 | ||
D | 10390 | ||
E | 10390 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2570 | ||
3 | |||
4 | 2670 | ||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5225 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 13700 | |
Oper. | 20900 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMP 121 | ||
---|---|---|---|
A | 7000 | ||
B | 11000 | ||
C | 11000 | ||
D | 11310 | ||
E | 11310 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2570 | ||
3 | |||
4 | 2670 | ||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5425 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 15500 | |
Oper. | 23600 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|