CZ 20 to 80
A cooling tower is a device that is designed to transfer heat from the specific manufacturing process of the atmosphere by the means of heat dissipation evaporative by lowering the temperature of the circulating water.
All models The LOCAL CURRENT, the CROSS) to 20, 40, 60, 80are manufactured from GRP (Polyester Reinforced fiberglass, with the introduction of the air blown into the current cross-referenced to the water, and have a vent in a forced manner, that is, from the outside to the inside, with a catchment, and the discharge of the air in a horizontal position so that the air flow is directed perpendicular to the water flow entering one or more vertical faces of the structure, and covering the whole height of the tower by the fan is an axial or centrifugal fan, and is suitable for water with a higher concentration of solids as a function of the ease of cleaning of the components and of the system of distribution of water in the channels that are open.
Get in touch with the team at the ALFATERM and schedule a service visit from one of our experienced engineers!
CZ 20
Model | CZ 20 | |
---|---|---|
A | 720 | |
B | 1900 | |
C | 900 | |
D | 2250 | |
E | 1140 | |
F | 1550 | |
G | 1760 | |
H | 260 | |
I | 1108 | |
J | 1350 | |
L | 3480 | |
M | 1300 | |
Connections | ||
V | 1" | |
W | 2" | |
X | 2" | |
Y | 2" | |
Z | 3/4" | |
The Volume of the water in the bowl | (L) | 400 |
with the fan weight (KG) | Emb. | 230 |
Oper. | 730 | |
with the fan-wheel weight (KG) | Emb. | 350 |
Oper. | 850 |
01. | THE CONNECTION TO THE V = DRAIN, THREADED BSP | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | CONNECT W OVERFLOW, THE THREAD BSP | ||||||||||||||
03. | THE CONNECTION TO THE X = THE ENTRANCE TO THE HOT WATER | ||||||||||||||
04. | THE CONNECTION OF THE Y = OUTPUT OF COLD WATER | ||||||||||||||
05. | CONNECTION TO Z-THE ENTRANCE TO THE WATER OF A REPLACEMENT, FAUCET SINGLE) | ||||||||||||||
06. | CONNECTIONS TO THE INLET AND THE OUTLET OF THE WATER THROUGH THE HOSE AND RUBBER | ||||||||||||||
07. | DIMENSIONS ARE IN MILLIMETERS (INCHES), UNLESS SPECIFICALLY STATED TO THE CONTRARY | ||||||||||||||
08. | L. F. A. = MAXIMUM SUPPLY ALFATERM | ||||||||||||||
09. | PROVIDE SUPPORT TO THE PIPING | ||||||||||||||
10. | HEIGHT OF THE BASE OF SUPPORT OF THE TOWER IS DEFINED BY THE CLIENT, AND IT SHOULD BE FLAT, SMOOTH AND LEVEL | ||||||||||||||
11. | PROVIDE FOR THE INSTALLATION OF A TOWER FAN TO BREATHE NEW LIFE INTO THE AIR, IN FAVOR OF THE BARRIERS TO THE FLOW OF AIR TO THE | ||||||||||||||
12. | ANCHOR BOLT AND THE MOUNTING OF THE FAN WHEEL IN THE DATABASE FOR THE CLIENT | ||||||||||||||
13. | THE PRESSURE REQUIRED AT THE INLET OF THE DOMESTIC HOT WATER, ACCORDING TO THE DATA SHEET | ||||||||||||||
14. | 'COLOR' = - FILLING-TYPE BLOCKS AND BARS IN THE SHAPE OF THE WAVES CROSSED, POLYPROPYLENE, POLYPROPYLENE, ANTI-FLAME, V-0 OR POLYPROPYLENE, ANTI-FLAME AND V-2 | ||||||||||||||
15. | 'BUS RAPID TRANSIT'=, FILLING TYPE, THE BARS OF A DROP-TUBE, POLYPROPYLENE, POLYPROPYLENE, ANTI-FLAME, V-0 OR POLYPROPYLENE, ANTI-FLAME AND V-2 | ||||||||||||||
16. | SUBJECT TO CHANGE WITHOUT NOTICE PRIOR | ||||||||||||||
An example of a specification |
|
CZ 40
Model | CZ 40 | |
---|---|---|
A | 920 | |
B | 2200 | |
C | 1100 | |
D | 2550 | |
E | 1340 | |
F | 2060 | |
G | 2260 | |
H | 360 | |
I | 1213 | |
J | 1560 | |
L | 3813 | |
M | 1500 | |
Connections | ||
V | 1" | |
W | 2" | |
X | 3" | |
Y | 3" | |
Z | 3/4" | |
The Volume of the water in the bowl | (L) | 800 |
with the fan weight (KG) | Emb. | 450 |
Oper. | 1410 | |
with the fan-wheel weight (KG) | Emb. | 605 |
Oper. | 1565 |
01. | THE CONNECTION TO THE V = DRAIN, THREADED BSP | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | CONNECT W OVERFLOW, THE THREAD BSP | ||||||||||||||
03. | THE CONNECTION TO THE X = THE ENTRANCE TO THE HOT WATER | ||||||||||||||
04. | THE CONNECTION OF THE Y = OUTPUT OF COLD WATER | ||||||||||||||
05. | CONNECTION TO Z-THE ENTRANCE TO THE WATER OF A REPLACEMENT, FAUCET SINGLE) | ||||||||||||||
06. | CONNECTIONS TO THE INLET AND THE OUTLET OF THE WATER THROUGH THE HOSE AND RUBBER | ||||||||||||||
07. | DIMENSIONS ARE IN MILLIMETERS (INCHES), UNLESS SPECIFICALLY STATED TO THE CONTRARY | ||||||||||||||
08. | L. F. A. = MAXIMUM SUPPLY ALFATERM | ||||||||||||||
09. | PROVIDE SUPPORT TO THE PIPING | ||||||||||||||
10. | HEIGHT OF THE BASE OF SUPPORT OF THE TOWER IS DEFINED BY THE CLIENT, AND IT SHOULD BE FLAT, SMOOTH AND LEVEL | ||||||||||||||
11. | PROVIDE FOR THE INSTALLATION OF A TOWER FAN TO BREATHE NEW LIFE INTO THE AIR, IN FAVOR OF THE BARRIERS TO THE FLOW OF AIR TO THE | ||||||||||||||
12. | ANCHOR BOLT AND THE MOUNTING OF THE FAN WHEEL IN THE DATABASE FOR THE CLIENT | ||||||||||||||
13. | THE PRESSURE REQUIRED AT THE INLET OF THE DOMESTIC HOT WATER, ACCORDING TO THE DATA SHEET | ||||||||||||||
14. | 'COLOR' = - FILLING-TYPE BLOCKS AND BARS IN THE SHAPE OF THE WAVES CROSSED, POLYPROPYLENE, POLYPROPYLENE, ANTI-FLAME, V-0 OR POLYPROPYLENE, ANTI-FLAME AND V-2 | ||||||||||||||
15. | 'BUS RAPID TRANSIT'=, FILLING TYPE, THE BARS OF A DROP-TUBE, POLYPROPYLENE, POLYPROPYLENE, ANTI-FLAME, V-0 OR POLYPROPYLENE, ANTI-FLAME AND V-2 | ||||||||||||||
16. | SUBJECT TO CHANGE WITHOUT NOTICE PRIOR | ||||||||||||||
An example of a specification |
|
CZ 60
Model | CZ 60 | |
---|---|---|
A | 1300 | |
B | 2200 | |
C | 1500 | |
D | 2650 | |
E | 1740 | |
F | 2520 | |
G | 2700 | |
H | 360 | |
I | 1608 | |
J | 2012 | |
L | 4208 | |
M | 1900 | |
Connections | ||
V | 1" | |
W | 2" | |
X | 3" | |
Y | 4" | |
Z | 3/4" | |
The Volume of the water in the bowl | (L) | 1100 |
with the fan weight (KG) | Emb. | 780 |
Oper. | 2080 | |
with the fan-wheel weight (KG) | Emb. | 1060 |
Oper. | 2360 |
01. | THE CONNECTION TO THE V = DRAIN, THREADED BSP | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | CONNECT W OVERFLOW, THE THREAD BSP | ||||||||||||||
03. | THE CONNECTION TO THE X = THE ENTRANCE TO THE HOT WATER | ||||||||||||||
04. | THE CONNECTION OF THE Y = OUTPUT OF COLD WATER | ||||||||||||||
05. | CONNECTION TO Z-THE ENTRANCE TO THE WATER OF A REPLACEMENT, FAUCET SINGLE) | ||||||||||||||
06. | CONNECTIONS TO THE INLET AND THE OUTLET OF THE WATER THROUGH THE HOSE AND RUBBER | ||||||||||||||
07. | DIMENSIONS ARE IN MILLIMETERS (INCHES), UNLESS SPECIFICALLY STATED TO THE CONTRARY | ||||||||||||||
08. | L. F. A. = MAXIMUM SUPPLY ALFATERM | ||||||||||||||
09. | PROVIDE SUPPORT TO THE PIPING | ||||||||||||||
10. | HEIGHT OF THE BASE OF SUPPORT OF THE TOWER IS DEFINED BY THE CLIENT, AND IT SHOULD BE FLAT, SMOOTH AND LEVEL | ||||||||||||||
11. | PROVIDE FOR THE INSTALLATION OF A TOWER FAN TO BREATHE NEW LIFE INTO THE AIR, IN FAVOR OF THE BARRIERS TO THE FLOW OF AIR TO THE | ||||||||||||||
12. | ANCHOR BOLT AND THE MOUNTING OF THE FAN WHEEL IN THE DATABASE FOR THE CLIENT | ||||||||||||||
13. | THE PRESSURE REQUIRED AT THE INLET OF THE DOMESTIC HOT WATER, ACCORDING TO THE DATA SHEET | ||||||||||||||
14. | 'COLOR' = - FILLING-TYPE BLOCKS AND BARS IN THE SHAPE OF THE WAVES CROSSED, POLYPROPYLENE, POLYPROPYLENE, ANTI-FLAME, V-0 OR POLYPROPYLENE, ANTI-FLAME AND V-2 | ||||||||||||||
15. | 'BUS RAPID TRANSIT'=, FILLING TYPE, THE BARS OF A DROP-TUBE, POLYPROPYLENE, POLYPROPYLENE, ANTI-FLAME, V-0 OR POLYPROPYLENE, ANTI-FLAME AND V-2 | ||||||||||||||
16. | SUBJECT TO CHANGE WITHOUT NOTICE PRIOR | ||||||||||||||
An example of a specification |
|
CZ 80
Model | CZ 80 | |
---|---|---|
A | 1600 | |
B | 2200 | |
C | 2000 | |
D | 2650 | |
E | 2240 | |
F | 2520 | |
G | 2700 | |
H | 360 | |
I | 1758 | |
J | 2235 | |
L | 4358 | |
M | 2400 | |
Connections | ||
V | 1" | |
W | 2" | |
X | 4" | |
Y | 4" | |
Z | 3/4" | |
The Volume of the water in the bowl | (L) | 1500 |
with the fan weight (KG) | Emb. | 1100 |
Oper. | 2850 | |
with the fan-wheel weight (KG) | Emb. | 1440 |
Oper. | 3190 |
01. | THE CONNECTION TO THE V = DRAIN, THREADED BSP | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | CONNECT W OVERFLOW, THE THREAD BSP | ||||||||||||||
03. | THE CONNECTION TO THE X = THE ENTRANCE TO THE HOT WATER | ||||||||||||||
04. | THE CONNECTION OF THE Y = OUTPUT OF COLD WATER | ||||||||||||||
05. | CONNECTION TO Z-THE ENTRANCE TO THE WATER OF A REPLACEMENT, FAUCET SINGLE) | ||||||||||||||
06. | CONNECTIONS TO THE INLET AND THE OUTLET OF THE WATER THROUGH THE HOSE AND RUBBER | ||||||||||||||
07. | DIMENSIONS ARE IN MILLIMETERS (INCHES), UNLESS SPECIFICALLY STATED TO THE CONTRARY | ||||||||||||||
08. | L. F. A. = MAXIMUM SUPPLY ALFATERM | ||||||||||||||
09. | PROVIDE SUPPORT TO THE PIPING | ||||||||||||||
10. | HEIGHT OF THE BASE OF SUPPORT OF THE TOWER IS DEFINED BY THE CLIENT, AND IT SHOULD BE FLAT, SMOOTH AND LEVEL | ||||||||||||||
11. | PROVIDE FOR THE INSTALLATION OF A TOWER FAN TO BREATHE NEW LIFE INTO THE AIR, IN FAVOR OF THE BARRIERS TO THE FLOW OF AIR TO THE | ||||||||||||||
12. | ANCHOR BOLT AND THE MOUNTING OF THE FAN WHEEL IN THE DATABASE FOR THE CLIENT | ||||||||||||||
13. | THE PRESSURE REQUIRED AT THE INLET OF THE DOMESTIC HOT WATER, ACCORDING TO THE DATA SHEET | ||||||||||||||
14. | 'COLOR' = - FILLING-TYPE BLOCKS AND BARS IN THE SHAPE OF THE WAVES CROSSED, POLYPROPYLENE, POLYPROPYLENE, ANTI-FLAME, V-0 OR POLYPROPYLENE, ANTI-FLAME AND V-2 | ||||||||||||||
15. | 'BUS RAPID TRANSIT'=, FILLING TYPE, THE BARS OF A DROP-TUBE, POLYPROPYLENE, POLYPROPYLENE, ANTI-FLAME, V-0 OR POLYPROPYLENE, ANTI-FLAME AND V-2 | ||||||||||||||
16. | SUBJECT TO CHANGE WITHOUT NOTICE PRIOR | ||||||||||||||
An example of a specification |
|